标题:From Radiotherapy Dataset to Cherenkov Dose Map: A Digital Linac Monte Carlo Simulation Pipeline

作者:Xianghuan He, Changyu Sun, Andy N. Wiles, Yao Hao, Gregory B. Biedermann, Brian W. Pogue, Rongxiao Zhang
查看论文《From Radiotherapy Dataset to Cherenkov Dose Map: A Digital Linac Monte Carlo Simulation Pipeline》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Background: Cherenkov-based radiotherapy monitoring depends on the relationship between dose and locally generated Cherenkov photons, before optical transport and detection. Purpose: To develop a DICOM RT-driven Geant4 digital linac Monte Carlo framework that scores dose and Cherenkov creation together and to evaluate their spatial correspondence. Methods: The framework converts DICOM CT, structure, plan, and dose objects into beam-delivery states and scores energy deposition and Cherenkov photon creation on a common 2.5-mm isotropic grid in a water-equivalent phantom. Static fields, different beam qualities, and a two-arc VMAT plan were tested. Monte Carlo dose was compared with TPS RTDOSE from Acuros XB and AAA; dose-Cherenkov associations and spatial agreement were assessed at voxel, plane, and profile levels. Results: Full-volume 3D dose gamma passing rates (3%/3 mm, 10% threshold) were 97.05%-98.86% for Acuros XB-referenced field-size and beam-quality cases (97.47% with AAA) and 97.84% for VMAT. Cherenkov creation correlated strongly with dose, with voxel $r^2 \geq 0.9890$ and projection/profile $r^2 \geq 0.9942$ in all cases. Dose-Cherenkov 3D gamma passing rates were 97.97%-99.16% for $10\times10$ 6X, 10X, and 15X fields and 96.59% for VMAT, but fell to 71.22% for $5\times5$ fields and 32.82% for 6FFF. Deviations were most apparent near small-field edges and along depth for 6FFF. Conclusions: In a homogeneous water phantom, local Cherenkov creation broadly tracks local dose but shows systematic differences at beam edges and with FFF beam quality. This framework supports future studies of optical transport and surface-based Cherenkov dosimetry.
评论: 31 pages, 9 figures
主题: 医学物理 (physics.med-ph)
引用方式: arXiv:2611.01408 [physics.med-ph]
  (或者 arXiv:2611.01408v1 [physics.med-ph] 对于此版本)
  https://doi.org/10.48550/arXiv.2611.01408

提交历史

来自:Xianghuan He
[v1] 2026年11月1日 星期日 01:42:36 UTC (1,076 KB)
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.med-ph
< 上一篇   |   下一篇 >
最新 | 近期 | 2026-11
切换浏览方式为:
physics

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站