跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

物理学 > 医学物理

arXiv:2611.03425 (physics)
[提交于 2026年11月2日]

标题:PET Attenuation Map Generation for Brain Imaging from Virtual Non-Contrast and Virtual Non-Iodine Images Obtained with Photon Counting CT Scanners

作者:Heba Alrakh, Lutz Tellmann, Omid Nikoubashman, Sadaf Shokrgozar, Claudia Regio Brambilla, Ahlam Said Mohamad Issa, Keith George Ciantar, Sebastian Faby, Ali Abu arra, Martin Wiesmann, Charlotte Weyland, N. Jon Shah, Christoph Lerche
查看论文《PET Attenuation Map Generation for Brain Imaging from Virtual Non-Contrast and Virtual Non-Iodine Images Obtained with Photon Counting CT Scanners》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:This study presents a transformation scheme for converting measured Hounsfield units (HUs) into linear attenuation coefficients (LACs) for 511 keV gamma photons in iodine contrast-enhanced angiographic CT images. The method is based on spectral CT data acquired from tissue-equivalent inserts of the Sun Nuclear electron density phantom. The resulting transformation will be used to develop an attenuation map template for our in-house developed BrainPET 7T system. Three approaches were used to obtain the attenuation maps. The first approach is based on angiographic spectral CT scans with iodinated contrast agent administration, and the computation of virtual non contrast (VNC) and virtual non-iodine (VNI) images. In this case, two images are combined: bone regions are segmented from the VNI images, and the corresponding voxel values in the VNC images are replaced, yielding a single quantitative monochromatic CT image. The second approach relies exclusively on VNC images, whereas the third approach uses only VNI images. The transformation schemes from HUs to LACs were established for different tube voltages (120 kV and 140 kV) and virtual monochromatic energies (64 keV, 67 keV, 70 keV, 76 keV, 80 keV, and 100 keV), showing the HUs dependency on the energy setting of the reconstructed virtual monochromatic energies. The accuracy and precision of the proposed transformation scheme were further evaluated using previously acquired angiographic CT datasets. Spectral CT can be expected to minimize the systematic error when converting HUs to LACs for 511 keV gamma rays using virtual monochromatic images (VMIs).
主题: 医学物理 (physics.med-ph)
引用方式: arXiv:2611.03425 [physics.med-ph]
  (或者 arXiv:2611.03425v1 [physics.med-ph] 对于此版本)
  https://doi.org/10.48550/arXiv.2611.03425

提交历史

来自:Heba Alrakh
[v1] 2026年11月2日 星期一 16:49:08 UTC (1,955 KB)
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.med-ph
< 上一篇   |   下一篇 >
最新 | 近期 | 2026-11
切换浏览方式为:
physics

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站