跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

凝聚态物理 > 软凝聚态物质

arXiv:2611.03949 (cond-mat)
[提交于 2026年11月2日]

标题:Thermodynamically consistent thixotropic viscoelastic modeling of human blood from a conformational free energy

作者:Thomas Martinod, Andrés Córdoba, Jay D. Schieber
查看论文《Thermodynamically consistent thixotropic viscoelastic modeling of human blood from a conformational free energy》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Structural thixotropic viscoelastic models describe the rheology of human blood accurately, but their structural kinetics are postulated, so their compatibility with the second law of thermodynamics is not guaranteed. We present ROUGE (ROUleaux model Guided by free Energy), a tensorial model of blood that describes the deformation of individual red blood cells and of rouleaux with two conformation tensors, and the degree of aggregation with a scalar variable. A single postulated Helmholtz free energy determines the stress, the relaxation of all three variables, and the entropy generation, so the model satisfies the second law in any flow. To build it, we extend a simplified formulation of nonequilibrium thermodynamics, which accounts for conformational energy and entropy, to microstructures described by several structural variables of different kinds. The coupling between aggregation and rouleaux deformation is motivated by the Langmuir adsorption of fibrinogen and is restricted so that the quiescent, fully aggregated state is the stable minimum of the free energy. Fits to published data for step-ups and step-downs in shear rate show that the fibrinogen binding sites remain far from saturation, so that the free energy has no adjustable parameters. They also show that rouleaux breakdown requires no empirical shear-activation term: the structure is destroyed in proportion to the work done by the flow on the aggregates, and a single structural time produces both breakdown within seconds and an algebraic recovery over tens of seconds. The resulting model has five well-determined parameters, and its fitted solvent viscosity coincides with that of plasma.
主题: 软凝聚态物质 (cond-mat.soft)
引用方式: arXiv:2611.03949 [cond-mat.soft]
  (或者 arXiv:2611.03949v1 [cond-mat.soft] 对于此版本)
  https://doi.org/10.48550/arXiv.2611.03949

提交历史

来自:Andrés Córdoba
[v1] 2026年11月2日 星期一 20:48:43 UTC (908 KB)
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

cond-mat.soft
< 上一篇   |   下一篇 >
最新 | 近期 | 2026-11
切换浏览方式为:
cond-mat

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站