跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

物理学 > 医学物理

arXiv:2611.06683 (physics)
[提交于 2026年11月4日]

标题:Experimental Assessment of Prompt Gamma Time Imaging in Complex Anatomy

作者:Pavel Kavrigin, Alicia Garnier, Adélie André, Chaima Abid, Yannick Boursier, Mathieu Dupont, Giuseppe Fanciulli, Laurent Gallin Martel, Marie-Laure Gallin Martel, Christophe Hoarau, Christian Morel, Jean-François Muraz, Maxime Pinson, Dimitrios Psarras, Nicola Toschi, Daniel Maneval, Sara Marcatili
查看论文《Experimental Assessment of Prompt Gamma Time Imaging in Complex Anatomy》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Prompt-gamma (PG) imaging is a promising approach for in vivo verification in proton therapy, but existing methods are primarily limited to reconstructing the PG emission profile, which provides only indirect information on proton transport. In this work, we introduce Prompt-Gamma Time Imaging (PGTI), an iterative reconstruction method based on the PG Timing (PGT) technique that jointly estimates the PG emission distribution and the proton velocity profile from Time-Of-Flight (TOF) measurements acquired with multiple detector modules. Unlike the PG distribution, the proton velocity is directly related to the stopping power and therefore provides access to both the tissue composition traversed by the beam and a first-order estimation of the delivered dose. The method was validated using experimental data acquired with the eight-module TIARA prototype previously developed by our collaboration. The anthropomorphic RANDO head phantom was irradiated with 100 MeV protons in two anatomical configurations representative of treatment planning and delivery, providing the first demonstration of PGTI under realistic conditions. In this example, the reconstructed material sequence agreed with the reference CT; despite ten bins presenting a misclassified material, the reconstructed proton range only differed from the expected value by approximately 1 mm. These results validate both the proposed PGTI framework and the use of the TIARA detector system in a pseudo-clinical environment, extending PG imaging beyond conventional range verification.
主题: 医学物理 (physics.med-ph)
引用方式: arXiv:2611.06683 [physics.med-ph]
  (或者 arXiv:2611.06683v1 [physics.med-ph] 对于此版本)
  https://doi.org/10.48550/arXiv.2611.06683

提交历史

来自:Sara Marcatili
[v1] 2026年11月4日 星期三 15:52:06 UTC (812 KB)
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.med-ph
< 上一篇   |   下一篇 >
最新 | 近期 | 2026-11
切换浏览方式为:
physics

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站