跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

物理学 > 医学物理

arXiv:2611.09002 (physics)
[提交于 2026年11月6日]

标题:Smart Spectral Doppler Ultrasound Imaging using Motion Tracking based on Wide-beam transmission and Neural Networks: Preliminary Results

作者:Jihye Baek, Allison Lee, Jinbum Kang, Yangmo Yoo
查看论文《Smart Spectral Doppler Ultrasound Imaging using Motion Tracking based on Wide-beam transmission and Neural Networks: Preliminary Results》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Ultrasound spectral Doppler imaging provides quantitative blood flow information for vascular diagnosis, but its accuracy is limited by the one-dimensional (1D) sample volume (SV). Motion from respiration, patient movement, and probe manipulation can move the target vessel out of the SV, causing spectral broadening, signal reduction, or loss of the spectrum. A two-dimensional (2D) SV can address this, but sequential focused-beam transmission reduces the pulse-repetition frequency (PRF), and plane-wave transmission lowers the signal-to-noise ratio (SNR). In this study, we propose a wide-beam transmission method that acquires a 2D SV from a single transmit event while preserving the PRF. A Hamming network, which requires no prior training, tracks axial and lateral motion within the 2D SV and updates the position of an adaptive 1D SV for each frame. Field II simulations showed that the wide-beam transmission had a spectral SNR comparable to that of focused-beam transmission and approximately 10 dB higher than that of plane-wave transmission. The motion tracking correctly detected the target position in over 93% of frames for vessel radii greater than 1 mm, and in 100% of frames for radii greater than 2 mm. In vivo studies of a carotid artery (linear array) and a hepatic vein (convex array) showed that the proposed method recovered obscured spectra and increased the spectral SNR by 9.3 dB and 4.5 dB, respectively. These results demonstrate that the proposed wide-beam transmission with Hamming network-based tracking can improve the accuracy of spectral Doppler imaging under tissue motion. Moreover, we anticipate that the proposed approach can be implemented in real-time due to its single transmission and simple two-layer architecture with low computational complexity.
主题: 医学物理 (physics.med-ph)
引用方式: arXiv:2611.09002 [physics.med-ph]
  (或者 arXiv:2611.09002v1 [physics.med-ph] 对于此版本)
  https://doi.org/10.48550/arXiv.2611.09002

提交历史

来自:Jihye Baek
[v1] 2026年11月6日 星期五 05:18:42 UTC (3,042 KB)
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.med-ph
< 上一篇   |   下一篇 >
最新 | 近期 | 2026-11
切换浏览方式为:
physics

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站