跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

电气工程与系统科学 > 图像与视频处理

arXiv:2611.09854 (eess)
[提交于 2026年11月6日 (v1),最后修订于 2026年11月23日 (此版本, v2)]

标题:Super-resolved digital terrain models for GEDI geolocation correction: agreement with airborne LiDAR DTM-based corrections at the beam level, not the footprint level

作者:Natsuki Yuda, Shinichiro Shirota
查看论文《Super-resolved digital terrain models for GEDI geolocation correction: agreement with airborne LiDAR DTM-based corrections at the beam level, not the footprint level》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:The Global Ecosystem Dynamics Investigation (GEDI) mission measures three-dimensional forest structure with a LiDAR instrument aboard the International Space Station. GEDI observations have geolocation errors of about 10 m, which cause misalignment with other remote sensing data and reduce the accuracy of downstream tasks. Matching GEDI ground elevations against high-resolution digital terrain models (DTMs) from airborne LiDAR is one way to correct these errors, but such DTMs exist in few regions. To widen this method's applicability, we super-resolved a more widely available low-resolution DTM for elevation matching. We ask whether a super-resolved DTM yields the same correction as a 1 m-resolution airborne LiDAR DTM and, if not, why. In steep forests of western Japan, we super-resolved an existing 10 m-resolution DTM to 1 m. Additionally fusing a global 30 m-resolution DTM from a different source substantially improved the accuracy. Using the resulting DTM, we corrected GEDI observation positions first by a single offset per ground track, then point by point. For most tracks, the per-track corrections nearly agreed with those from the airborne LiDAR DTM. Point-by-point corrections, however, did not agree. This was because the error of the generated DTM was close to the elevation differences that point-by-point correction must resolve, and most of this error lay at scales that even a 10 m-resolution DTM can represent. Under similar conditions, a super-resolved DTM may be usable in place of a 1 m-resolution DTM for per-track correction, but improving the accuracy, or using it for point-by-point correction as well, requires reducing the error at these scales rather than reproducing fine relief.
评论: 34 pages, 12 figures, 18 tables
主题: 图像与视频处理 (eess.IV); 计算机视觉与模式识别 (cs.CV); 地球物理 (physics.geo-ph)
引用方式: arXiv:2611.09854 [eess.IV]
  (或者 arXiv:2611.09854v2 [eess.IV] 对于此版本)
  https://doi.org/10.48550/arXiv.2611.09854

提交历史

来自:Natsuki Yuda
[v1] 2026年11月6日 星期五 18:36:50 UTC (6,620 KB)
[v2] 2026年11月23日 星期一 18:59:46 UTC (6,149 KB)
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

eess.IV
< 上一篇   |   下一篇 >
最新 | 近期 | 2026-11
切换浏览方式为:
eess
cs.CV
physics.geo-ph

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站