跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

物理学 > 医学物理

arXiv:2611.10142 (physics)
[提交于 2026年11月6日]

标题:Towards in vivo photon dosimetry using radiation-sensitive mixed-core ultrasound phase-change contrast agents

作者:Bram Carlier, Reza Bahrami Gorji, Qingyuan Tan, Meritxell Gambús-Marfà, Uwe Himmelreich, Meng-Xing Tang, Koen Van Den Abeele, Sophie V. Heymans
查看论文《Towards in vivo photon dosimetry using radiation-sensitive mixed-core ultrasound phase-change contrast agents》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Objective. Advanced radiotherapy applies complex treatment plans that require verification of the beam delivery. Therefore, in vivo dosimetry, measuring delivered radiation doses directly on the patient, has become increasingly important. Radiation-sensitive phase-change nanodroplets were recently proposed for in vivo radiation sensing. The radiation-induced conversion of superheated nanodroplets into microbubbles generates ultrasound contrast from which radiation deposition can be derived. While successful for in vivo proton range verification, previously used nanodroplet formulations were not suitable for in vivo photon dosimetry due to stringent requirements on the degree of superheat of the nanodroplet core. Here, we used a mixed-core strategy, combining different perfluorocarbons in the same nanodroplet core, to modulate the photon response and droplet stability at body temperature. Approach. Lipid-shelled nanodroplets with different cores (pure octafluoropropane, pure decafluorobutane and a 17:4 (v/v) octafluoropropane:decafluorobutane mixture) were dispersed in deionized water in phantom containers and irradiated with a photons at various temperatures. Simultaneous high-frame rate ultrasound acquisition allowed to link ultrasound contrast generation to the radiation delivery. Nanodroplets were characterized using 19F NMR spectroscopy. Main results. Photons induced nanodroplet-mediated ultrasound contrast strong enough for clinical applications at body temperature. A clear trade-off was observed between a stronger photon response and maintaining sufficient droplet stability. Neither octafluoropropane (lacking stability) nor decafluorobutane (lacking photon response) cores proved suitable. On the contrary, the mixed-core formulation exhibited a strong photon response with minimal background already at small radiation doses (0.1 Gy). This paves the way for future in vivo dosimetry.
评论: 21 pages, 9 figures + 3 supplementary figures, submitted to Physics in Medicine & Biology
主题: 医学物理 (physics.med-ph)
引用方式: arXiv:2611.10142 [physics.med-ph]
  (或者 arXiv:2611.10142v1 [physics.med-ph] 对于此版本)
  https://doi.org/10.48550/arXiv.2611.10142

提交历史

来自:Bram Carlier
[v1] 2026年11月6日 星期五 19:07:12 UTC (1,506 KB)
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.med-ph
< 上一篇   |   下一篇 >
最新 | 近期 | 2026-11
切换浏览方式为:
physics

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站