跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

物理学 > 医学物理

arXiv:2611.10460 (physics)
[提交于 2026年11月7日]

标题:Noise Propagation and Non-Uniqueness in Three-Material Dual Energy CT with a Path Length Constraint

作者:Andrew E. Ferretti, Emil Y. Sidky, JP Phillips, Xiaochuan Pan
查看论文《Noise Propagation and Non-Uniqueness in Three-Material Dual Energy CT with a Path Length Constraint》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Objective: Using a path length constraint with dual energy computed tomography (DECT) data, a sample can be decomposed into three basis materials. We aim to analyze the stability of such a system by presenting a noise propagation framework for optimizing the contrast to noise ratio (CNR) of virtual monochromatic images (VMIs) and by studying instances where sinogram decompositions are not unique. Approach: We extend a noise propagation framework developed for two-material DECT to three materials. Using the Jacobian of the system, we identify tube voltage pairings with good noise properties and obtain analytical expressions for VMI CNR. We apply spectral theorem to identify the best CNR possible in a linear combination of basis images. By using a reduced two-dimensional problem, we develop the sampling isoline recovery algorithm (SIRA) to study non-unique sinogram decompositions in this system. Main results: Using our noise propagation framework with a realistic breast phantom consisting of adipose, glandular tissue, and iodine, we find an ideal tube pairing of 34 kVp and 69 kVp, and a maximum VMI CNR of a spiculated lesion of 9.9. By allowing arbitrary linear combinations of basis material images, we find a CNR of 10.2 can be achieved. In a realistic phantom with a cardiac plaque, we find non-unique water, bone and iodine decompositions, and show that qualitatively accurate reconstructions can be obtained using SIRA. Significance: We developed a framework for direct optimization of VMI CNR in a three-material DECT decomposition and showed that an arbitrary linear combination of basis material images can achieve a higher CNR than a strict VMI. We demonstrate the presence of non-unique sinogram decompositions in three-material DECT with a data constraint.
评论: 20 pages, 8 figures. Submitted to Physics in Medicine and Biology
主题: 医学物理 (physics.med-ph)
引用方式: arXiv:2611.10460 [physics.med-ph]
  (或者 arXiv:2611.10460v1 [physics.med-ph] 对于此版本)
  https://doi.org/10.48550/arXiv.2611.10460

提交历史

来自:Andrew Ferretti
[v1] 2026年11月7日 星期六 04:20:16 UTC (1,614 KB)
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.med-ph
< 上一篇   |   下一篇 >
最新 | 近期 | 2026-11
切换浏览方式为:
physics

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站