跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

物理学 > 医学物理

arXiv:2611.12584 (physics)
[提交于 2026年11月9日]

标题:Vendor-Agnostic Pseudocontinuous Arterial Spin Labeling Using Pulseq: Cross-Vendor Quantitative Evaluation

作者:Jianing Zhang, Jun Wang, Joseph G. Woods, Shaoyou Ye, Shuai Ming, Hongwei Li, Wei Hu, Wei Wei, Xiaohu Li, Thomas W. Okell, Yang Ji
查看论文《Vendor-Agnostic Pseudocontinuous Arterial Spin Labeling Using Pulseq: Cross-Vendor Quantitative Evaluation》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Purpose: Inter-scanner variability in cerebral blood flow (CBF) quantification limits reproducibility in multi-center arterial spin labeling (ASL) studies. We developed and validated a vendor-agnostic pseudo-continuous ASL (PCASL) sequence using the open-source Pulseq framework, and assessed its extensibility to advanced perfusion imaging. Methods: A vendor-independent PCASL sequence was implemented in Pulseq and deployed on 3T scanners from Siemens, GE, and United Imaging. Seven healthy volunteers underwent single-post-labeling-delay (PLD) PCASL on all platforms, including test-retest scans. An in-house adapted Siemens vendor-based PCASL sequence served as reference. Reproducibility was assessed using within-subject coefficient of variation (CVwithin), root mean square error (RMSE), regional CBF correlation, and voxel-wise variation ratio maps. Multi-PLD PCASL and planning-free VE-PCASL were implemented as proof-of-concept extensions. Results: Mean gray matter (GM) CBF was similar across implementations. Test-retest GM CVwithin was below 4% on all platforms; Siemens-Pulseq had the lowest value (2.65%), versus 3.64% for the native sequence. GM RMSE between Siemens-Vendor and Pulseq implementations was comparable to test-retest RMSE, and all inter-scanner CVwithin values were below 3%. Voxel-wise variation ratio distributions were centered near 100%, suggesting cross-vendor variability comparable to physiological baseline fluctuations. Multi-PLD and VE-PCASL ran successfully on all platforms, yielding consistent CBF/ATT maps and vascular territory delineations. Conclusion: Pulseq-based PCASL enables vendor-agnostic perfusion imaging with low inter-scanner variability. This open-source approach provides a reproducible, standardized solution for multi-center ASL studies and facilitates deployment of advanced ASL techniques in clinical research.
主题: 医学物理 (physics.med-ph)
引用方式: arXiv:2611.12584 [physics.med-ph]
  (或者 arXiv:2611.12584v1 [physics.med-ph] 对于此版本)
  https://doi.org/10.48550/arXiv.2611.12584

提交历史

来自:Jianing Zhang
[v1] 2026年11月9日 星期一 15:37:58 UTC (1,704 KB)
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.med-ph
< 上一篇   |   下一篇 >
最新 | 近期 | 2026-11
切换浏览方式为:
physics

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站