标题:An improved statistical treatment for radioassay-based background projection incorporating part-to-part variation
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读摘要:For low background experiments, prediction of the background from radioactivity in detector components is of critical importance. Radioassays are often conducted on small samples or individual parts, which may be subject to differences in production or handling resulting in a part-to-part variation. This part-to-part variation can have an impact on the total activity and is not presently captured by the averaging methods used to evaluate radioassays. We propose a new method for the averaging of radioassays to incorporate this part-to-part variation into predictions of the total activity of parts. We also consider how to add component activities based on assays for component groups that are simulated as a single entity.