摘要:The polarisation correlation of the two annihilation photons, measured by Compton polarimetry, has been proposed as a PET biomarker of tissue microstructure. We quantify how many events this measurement needs, what limits that number and whether a small-animal CZT system reaches tissue-level contrasts. We parameterise the measurement by the correlation coefficient $\kappa$ ($\kappa=1$ maximally entangled, $1/2$ separable), derive the classical Fisher information of double-Compton events and compare it with the quantum Fisher information, relate $\kappa$ to the annihilation channels of positronium in tissue, and simulate pixelated CdZnTe (CZT) rings. The model is validated against three published measurements and an independent GATE/Geant4 simulation. A double-Compton event carries at most 0.12-0.14 units of Fisher information about $\kappa$ and 0.015 on average, 0.1-0.6% of the quantum limit. Event-wise maximum likelihood reaches the Cramer-Rao bound, whereas the conventional ratio R needs 1.2-2.3 times as many events. The observed coefficient is $\kappa_{obs}=1-\alpha(1-\kappa_{pick})$ with a pick-off share $\alpha$ of 0.13-0.29; it is sensitive to lipid fraction but not to oxygen, and published porous-polymer data give $\kappa_{pick}$ = 0.34-0.58. In a 15-mm CZT module, ordering ambiguity, position errors and electron transport halve the information per event, and sequence reconstruction recovers it. With $^{18}$F and an eight-module ring, $\kappa$ is measured to $\pm0.01$ in a 10-mm tumour with half of its decays, whereas separating tissues by $\kappa$ alone requires 6-74 times more decays than available.
评论: 27 pages, 8 figures, 8 tables. Code and data: doi:10.5281/zenodo.24302646. v2: revised title and author list; corrected the identification of family A in Appendix A (t_3 = 1 - 2 kappa); figures redrawn; abstract shortened
主题: 量子物理 (quant-ph)
引用方式: arXiv:2611.21022 [quant-ph]
  (或者 arXiv:2611.21022v2 [quant-ph] 对于此版本)
  https://doi.org/10.48550/arXiv.2611.21022

提交历史

来自:Jianyong Hu
[v1] 2026年11月16日 星期一 12:40:52 UTC (200 KB)
[v2] 2026年11月25日 星期三 14:05:14 UTC (259 KB)
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

quant-ph
< 上一篇   |   下一篇 >
最新 | 近期 | 2026-11

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站