标题:Geometry-bridge flow matching for blind rigid-motion correction in head cone-beam CT

作者:Sungho Yun, Seungryong Cho
查看论文《Geometry-bridge flow matching for blind rigid-motion correction in head cone-beam CT》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Rigid motion of a patient head during head cone-beam CT (CBCT) scan can degrade image quality and complicate recovery of accurate anatomical structures from the measured projections. We present a 3D flow-matching prior approach that learns the image changes induced by motion. Its geometry-bridge connects motion-corrupted and motion-free Feldkamp-Davis-Kress (FDK) reconstructed images of the same source volume through progressively reduced simulated motion. The forward projector's geometry derivative supplies analytic velocity targets along this path. A plug-and-play loop encompasses the learned image updates together with spline-based pose estimation, conjugate-gradient data consistency, and image total-variation regularization. Both the refined image volume and the FDK reconstructed image volume at the estimated poses are evaluated. On simulated 360-view scans from 30 held-out CQ500 patients with nominal per-component motion amplitudes within 10 mm / 10 degrees, the framework achieved state-of-the-art image reconstruction quality and motion accuracy in comparison with other methos such as learned autofocus and diffusion-based joint reconstruction. Mean peak signal-to-noise ratio (PSNR) reached 37.1 dB and mean detector-plane reprojection error (RPE) was 0.27 mm. With matched endpoints at the inference settings, the geometry bridge improved PSNR by 1.6 dB and reduced RPE by 33% relative to image-linear training. With 50 prior updates and coarse-to-fine motion estimation, total processing time averaged 9.1 minutes per patient on an RTX A6000.
主题: 医学物理 (physics.med-ph); 计算与语言 (cs.CL); 计算机视觉与模式识别 (cs.CV)
引用方式: arXiv:2611.23788 [physics.med-ph]
  (或者 arXiv:2611.23788v2 [physics.med-ph] 对于此版本)
  https://doi.org/10.48550/arXiv.2611.23788

提交历史

来自:Sungho Yun PhD
[v1] 2026年11月18日 星期三 03:51:56 UTC (1,774 KB)
[v2] 2026年11月19日 星期四 05:08:07 UTC (1,774 KB)
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.med-ph
< 上一篇   |   下一篇 >
最新 | 近期 | 2026-11
切换浏览方式为:
physics
cs.CL
cs.CV

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站