物理学 > 仪器与探测器
[提交于 2026年11月13日]
标题:Towards Automatic Ion Identification in Storage Rings
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读摘要:Resonant Schottky detectors provide non-destructive, single-ion-sensitive measurements of revolution frequencies and intensities of ion species stored in a heavy-ion storage ring. These high-\(Q\) cavities allow analysis of high-order harmonics of the revolution frequencies to magnify absolute frequency separations. Adjacent harmonic ranges can, however, overlap within the detector band, making frequency alone insufficient for determining the ion's mass-to-charge ratio $(m/q)$. We present a proof-of-concept for an automated harmonic de-overlapping method using spectral shapes in combined Schottky and Isochronous Mass Spectrometry. The empirical ansatz is that, for a fixed ion-optical setting, each peak, corresponding to a specific ion species with given $m/q$ ratio, has a characteristic profile that evolves smoothly with changing $m/q$. Occurrences of the same local structure at different harmonics should therefore retain almost identical shapes after frequency rescaling. Applied to a 245\,MHz spectrum accumulated from 11\,452 injections at the Experimental Storage Ring at GSI, the method organizes 16 of 32 detected structures into five candidate families and reconstructs their fundamental-frequency representation. Reducing the complex mixed-harmonic spectrum to this smaller candidate set solves the challenging task of finding initial anchors for the ion identification.
提交历史
来自:David Freire Fernández[v1] 2026年11月13日 星期五 12:22:40 UTC (1,114 KB)