标题:Label-free self-calibration of a segmented HPGe $\gamma$-ray tracking array from the Compton scattering constraint

作者:Mojahed Abushawish, Jérémie Dudouet, Olivier Stézowski, José Manuel Udías
查看论文《Label-free self-calibration of a segmented HPGe $\gamma$-ray tracking array from the Compton scattering constraint》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Pulse-shape analysis in segmented HPGe $\gamma$-ray tracking arrays such as AGATA relies on reference signals for known interaction positions, which are costly to measure and only approximate when calculated. In a simulation of 51 AGATA crystals, we show that the interaction positions can be learned from the pulses without position labels. For a \Co\ photon that is Compton scattered in one segment and absorbed in another, the scattering angle follows both from the deposited energies and from the positions of the source and of the two interactions. A neural network shared by all crystals predicts one position per fired segment and is trained only to make these two angles agree; the unmeasured order of the two interactions and the selection of the pairs are revised during training. The pulses, synthesised from AGATAGeFEM bases for $2.79\times10^{6}$ pairs of fired segments whose energies add up to a \Co\ line, selected from $4\times10^{7}$ simulated decays, include noise, cross-talk, trigger-time jitter and differences between crystals. For the hits of held-out pairs, the mean three-dimensional position error falls from 10.4~mm with the segment centres to 1.65~mm, with a FWHM of 1.0--1.3~mm in each coordinate, compared with 1.07~mm for the same network trained on the simulated positions. The constraint determines the positions along the crystal axes only weakly, and at small scattering angles it pulls low-energy first interactions towards the source, which is why deposits below 200~keV are excluded. Even with the simulated positions, the two angles differ, mainly because a segment with several interactions is described by a single position and energy rather than because of Doppler broadening.
主题: 仪器与探测器 (physics.ins-det)
引用方式: arXiv:2611.28142 [physics.ins-det]
  (或者 arXiv:2611.28142v1 [physics.ins-det] 对于此版本)
  https://doi.org/10.48550/arXiv.2611.28142

提交历史

来自:Mojahed Abushawish
[v1] 2026年11月19日 星期四 10:30:36 UTC (453 KB)
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.ins-det
< 上一篇   |   下一篇 >
最新 | 近期 | 2026-11
切换浏览方式为:
physics

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站