跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

电气工程与系统科学 > 图像与视频处理

arXiv:2611.28184 (eess)
[提交于 2026年11月20日]

标题:Beyond Outlier Rejection: Transient-Aware Reconstruction of Multi-Stack MRI

作者:Anika Knupfer, Maximilian Lindholz, Maria Camila Bustos-Vivas, Joseph V. Hajnal, Bodo Rosenhahn, Jana Hutter
查看论文《Beyond Outlier Rejection: Transient-Aware Reconstruction of Multi-Stack MRI》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Clinical MRI typically acquires the organ of interest as consecutive stacks of 2D slices in different orientations. Reconstruction methods such as SVRTK and NeSVoR fuse them into one volume and down-weight what does not fit, although in living tissue the change during the scan is often the signal itself and can contain clinically relevant physiological information, such as fetal motion and uterine contraction. We propose an analysis-by-synthesis decomposition that explains every acquired voxel through its exact acquisition geometry as a static anatomy shared by all stacks, a rigid and smooth non-rigid motion per stack, and a sparse transient field per stack for changes during one acquisition only. A robust reweighting keeps such changes out of the anatomy. The model is fitted per subject without training data, with one configuration for all datasets. On a digital phantom with known ground truth, static changes are kept entirely in the anatomy, and the transient field of the stack that saw a transient recovers 68% of it at 12mm radius. From identical inputs, the anatomy predicts held-out stacks better than SVRTK and NeSVoR on uterine (NCC 0.897 against 0.874 and 0.863, 123 patients) and on prostate MRI from unseen sites and scanners (0.847 against 0.795 and 0.757, 85 patients), and on fetal brain MRI as well as SVRTK and better than NeSVoR (0.771 against 0.763 and 0.747, 83 fetuses). The transient fields flag corrupted fetal slices with an AUROC of 0.94 against expert raters. As the input of a frozen anomaly detector trained on healthy subjects only, the anatomy localizes radiologist-delineated uterine lesions better than the SVRTK and NeSVoR volumes (AUROC 0.76 against 0.71 and 0.71, 37 patients).
评论: 11 pages, 6 Figures
主题: 图像与视频处理 (eess.IV); 计算机视觉与模式识别 (cs.CV)
引用方式: arXiv:2611.28184 [eess.IV]
  (或者 arXiv:2611.28184v1 [eess.IV] 对于此版本)
  https://doi.org/10.48550/arXiv.2611.28184

提交历史

来自:Anika Knupfer
[v1] 2026年11月20日 星期五 11:50:13 UTC (11,307 KB)
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

eess.IV
< 上一篇   |   下一篇 >
最新 | 近期 | 2026-11
切换浏览方式为:
eess
cs.CV

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站