标题:Conceptual Design of a 5 MV High-Voltage System for a Compact Orbitron Fusion Device

作者:Moein Borghei, Robin Langtry, Nicola Van Moon, Matthew Affolter, Erik McKee
查看论文《Conceptual Design of a 5 MV High-Voltage System for a Compact Orbitron Fusion Device》的 PDF
查看中文 PDF 查看原文 PDF EasyResearch 阅读
摘要:The high-voltage system is a key part of the puzzle toward achieving net-positive fusion power in a compact Orbitron device. This paper presents a conceptual engineering design for a 5 MV, 20 mA, 100 kW HV system for a next-generation Orbitron, serving as an upper-bound design point for the HV system. The MC-TRANS++ 0-D code is used to set the load requirements: a 1 m long, 0.45 m first-wall-radius central cell, 2.5 T on-axis and 10 T mirror-throat fields, and a 5 MV radial potential drop sustaining supersonic rotation ($M = 4.8$). This delivers a triple product of $5.8 \times 10^{21}$ keV s /m3 and $Q_{sci}$ = 8.5. The HV power supply integrates an AC-DC converter, a SiC full-bridge inverter, a CLLC resonant network with an air-core step-up transformer, and feeds a 120-stage parallel-fed series-cascaded rectifier operating at 250 kHz. At full load, this architecture yields an end-to-end efficiency of 85%, much higher than the 60% typical of triode-driven MV-class power supplies. The 5 MV voltage is delivered to a radially nested 50-gap bushing system that interfaces pressurized insulating gas to high vacuum, using brazed alumina spacers with a corrugated profile. The design draws directly on the measured behavior of a previously demonstrated 300 kV prototype, from which six quantitative lessons are extracted and mapped onto the 5 MV design. Electrostatic simulations of the complete assembly at rated voltage show maximum surface fields of 30.3 MV/m on the corona rings, 7.7 MV/m at the cathode triple junction, and average vacuum-gap fields ranging from 5.5 to 40 MV/m. These field strengths remain below breakdown thresholds due to the implementation of triple-junction shielding, insulation corrugation, and axial magnetic insulation at 2.5-10 T. The conceptual system has a form factor of 2.7 meters in diameter and 6.5 meters in length, projected to deliver a net power output of 86-171 kWe.
主题: 应用物理 (physics.app-ph)
引用方式: arXiv:2611.28658 [physics.app-ph]
  (或者 arXiv:2611.28658v1 [physics.app-ph] 对于此版本)
  https://doi.org/10.48550/arXiv.2611.28658

提交历史

来自:Moein Borghei
[v1] 2026年11月21日 星期六 08:38:47 UTC (6,068 KB)
全文链接:

访问论文:

  • 查看中文 PDF
  • 查看原文 PDF
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.app-ph
< 上一篇   |   下一篇 >
最新 | 近期 | 2026-11
切换浏览方式为:
physics

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站