标题:Diffusion Posterior Sampling for Mitigation of Spatially-Variant System Blur in Ultra-High-Resolution CT of Trabecular Bone

作者:T. Ye, G. Shi, A. Sivakumar, F. J. Quevedo Gonzalez, K. F. Moseley, J. A. Carrino, J. H. Siewerdsen, W. Zbijewski
查看论文《Diffusion Posterior Sampling for Mitigation of Spatially-Variant System Blur in Ultra-High-Resolution CT of Trabecular Bone》的 PDF
查看中文 PDF 查看原文 PDF EasyResearch 阅读
摘要:Objective: CT spatial resolution degrades with distance from isocenter. We evaluate diffusion posterior sampling (DPS) deblurring for restoring structural detail and harmonizing texture features (TFs) of off-center trabecular bone to isocenter in ultra-high resolution CT (UHR CT). Methods: DPS pairs a diffusion prior, trained on isocenter UHR CT patches of trabecular bone from four human femora, with a likelihood term enforcing consistency with the observed image. Two variants were tested on a held-out femur at radial shifts of 90, 130 and 160 mm: KnownBlurDPS, with an anisotropic Gaussian kernel derived from modulation transfer function measurements, and BlindDPS, which estimated the kernel jointly with the image. Restored patches were compared with isocenter ground truth by structural similarity (SSIM), gradient magnitude similarity deviation (GMSD), and concordance correlation coefficient (CCC) of 40 gray-level co-occurrence and run-length TFs. Results: Both DPS variants improved SSIM and GMSD by 1-10% and mean TF CCC by 30-130%. The number of reproducible TFs (CCC > 0.80) at 90/130/160 mm rose from 13/2/1 without deblurring to 33/35/29 (KnownBlurDPS) and 40/36/16 (BlindDPS). At 90 mm, the accuracy of a linear classifier predicting the shift from TFs dropped from 79% to chance level with BlindDPS. Conclusion: DPS partly restores trabecular detail and TF reproducibility lost to spatially-variant blur in UHR CT; the blind variant matches the measured-kernel variant up to 130 mm. Significance: DPS deblurring can standardize trabecular bone TFs against patient mis-centering, potentially improving the robustness of TF-based CT radiomics; its blind form needs no CT system characterization.
主题: 医学物理 (physics.med-ph)
引用方式: arXiv:2611.29219 [physics.med-ph]
  (或者 arXiv:2611.29219v1 [physics.med-ph] 对于此版本)
  https://doi.org/10.48550/arXiv.2611.29219

提交历史

来自:Tianyi Ye
[v1] 2026年11月22日 星期日 04:37:25 UTC (1,430 KB)
全文链接:

访问论文:

  • 查看中文 PDF
  • 查看原文 PDF
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.med-ph
< 上一篇   |   下一篇 >
最新 | 近期 | 2026-11
切换浏览方式为:
physics

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站