跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

物理学 > 原子物理

arXiv:2611.29785 (physics)
[提交于 2026年11月22日]

标题:Low Vibration Closed-Cycle Flow Cryostat for Ion-Cavity Experiments

作者:Andrew Laugharn
查看论文《Low Vibration Closed-Cycle Flow Cryostat for Ion-Cavity Experiments》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Cryogenic operation below 10 K suppresses trap-electrode and dielectric heating of trapped ions while cryopumping residual gases to ultra-high vacuum (UHV) without requiring a bakeout. These advantages are particularly important for cavity-integrated ion traps, where nearby dielectric surfaces can increase motional heating and rapid design-build-test iterations benefit from eliminating bakeout cycles. We have developed a custom 4 K cryostat cooled by a ColdEdge Technologies (CET) Stinger closed-cycle $^{4}\text{He}$ flow cryogenic system to study various ion trap optical cavity structures designed to serve as a photonic interconnect between remote, compute-capable trapped $^{171}\text{Yb}^{+}$ ion quantum processors, enabling long baseline entanglement distribution $(>10\text{ km})$. We integrate an Alpine Quantum Technologies (AQT) Paul trap and Fabry-P\'erot optical cavity at the 4 K stage. The cooling capacities of the cryostat 40 K and 4 K stages were measured to be 5 W at 45 K and 0.5 W at 6.1 K. Vibrations of the 4 K stage relative to the optical table are less than $12\text{ nm}_{\text{RMS}}$ in three dimensions, as measured using a Michelson interferometer. An ultra-high vacuum (UHV) is inferred by studying the rate of hydrogen-$\mathrm{Yb}^{+}$ ion collisions. Ion storage times exceeding 5 days without laser cooling have been reported and the position of the trapped ions are reproducible within $\sim10\text{ }\mu\text{m}$ following repeated thermal cycles to room temperature. The uptime of this system is 72 days and offers convenient access to the 4 K stage for in-vacuum maintenance and system modifications. Using this platform, we demonstrate spatial overlap and interaction between a trapped $^{174}\text{Yb}^{+}$ ion and the optical cavity mode on the 1345 nm transition, establishing preliminary experimental validation of the integrated cryogenic ion-cavity structure.
主题: 原子物理 (physics.atom-ph)
引用方式: arXiv:2611.29785 [physics.atom-ph]
  (或者 arXiv:2611.29785v1 [physics.atom-ph] 对于此版本)
  https://doi.org/10.48550/arXiv.2611.29785

提交历史

来自:Andrew Laugharn
[v1] 2026年11月22日 星期日 21:34:09 UTC (32,988 KB)
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.atom-ph
< 上一篇   |   下一篇 >
最新 | 近期 | 2026-11
切换浏览方式为:
physics

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站