标题:Comparison of 3D-DXA Measurements with QCT Software Solutions for Proximal Femur Bone Density Assessment

作者:Asier Muñoz, Luis del Rio, Jorge Malouf, Ludovic Humbert
查看论文《Comparison of 3D-DXA Measurements with QCT Software Solutions for Proximal Femur Bone Density Assessment》的 PDF
查看中文 PDF 查看原文 PDF EasyResearch 阅读
摘要:3D-Shaper reconstructs proximal femur shape and density in 3D from a standard hip dual-energy X-ray absorptiometry (DXA) scan. In men and women aged 35-91 years, we compared 3D-Shaper integral volumetric bone mineral density (vBMD), trabecular vBMD, and cortical surface BMD (sBMD) with quantitative computed tomography (QCT) processed with three methods: an in-house pipeline, Stradview and QCTPro CTXA, which were used to derive bone measurements equivalent to those of 3D-Shaper. Agreement, including among QCT methods, was assessed with linear regression and Bland-Altman analysis (bias and limits of agreement, LoA). 3D-Shaper agreed strongly with the in-house pipeline and Stradview for integral vBMD (R=0.95-0.96; bias 1.5 to 4.2 mg/cm$^3$; LoA $\pm$39.7 to 41.4 mg/cm$^3$), trabecular vBMD (R=0.92-0.94; bias -11.8 to -7.8 mg/cm$^3$; LoA $\pm$33.3 to 39.4 mg/cm$^3$) and cortical sBMD (R=0.94; bias 5.6 to 38.2 mg/cm$^2$; LoA $\pm$23.6 to 26.4 mg/cm$^2$). The in-house pipeline and Stradview agreed for integral vBMD (R=1.00; bias -2.7 mg/cm$^3$; LoA $\pm$3.7 mg/cm$^3$), trabecular vBMD (R=0.96-1.00; bias -0.2 to 3.9 mg/cm$^3$; LoA $\pm$6.9 to 27.5 mg/cm$^3$) and cortical sBMD (R=0.98; bias 32.7 mg/cm$^2$; LoA $\pm$14.6 mg/cm$^2$). Compared with 3D-Shaper, QCTPro CTXA integral vBMD was systematically lower (R=0.90; bias -28.4 mg/cm$^3$; LoA $\pm$61.5 mg/cm$^3$) and trabecular vBMD showed a proportional bias (R=0.89; bias -44.1 mg/cm$^3$; LoA $\pm$61.3 mg/cm$^3$). The same pattern was observed against the other QCT methods, for integral vBMD (R=0.93; bias -32.6 to -29.9 mg/cm$^3$; LoA $\pm$49.6 to 50.0 mg/cm$^3$) and trabecular vBMD (R=0.94-0.96; bias -36.3 to -32.5 mg/cm$^3$; LoA $\pm$51.2 to 54.9 mg/cm$^3$). These findings support the agreement of 3D-Shaper with independent QCT approaches and show that 3D-Shaper-QCT differences must be interpreted in light of the QCT method used.
主题: 定量方法 (q-bio.QM)
引用方式: arXiv:2611.30743 [q-bio.QM]
  (或者 arXiv:2611.30743v1 [q-bio.QM] 对于此版本)
  https://doi.org/10.48550/arXiv.2611.30743

提交历史

来自:Ludovic Humbert
[v1] 2026年11月23日 星期一 14:21:13 UTC (2,169 KB)
全文链接:

访问论文:

  • 查看中文 PDF
  • 查看原文 PDF
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

q-bio.QM
< 上一篇   |   下一篇 >
最新 | 近期 | 2026-11
切换浏览方式为:
q-bio

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站