数学 > 概率论
[提交于 2026年11月23日]
标题:Closed-Form Formula for $d_{\mathrm{critical}}(a_0)$ in Large Fully Connected Power Grids
查看中文 PDF 查看原文 PDF EasyResearch 阅读摘要:Kadloor and Santhi (arXiv:1011.4098) modeled cascading failures in a large fully connected power grid by a coupled four-variable recursion for the minimum surviving load $a_n$, the mean failed load $\mu_{n-1}$, the redistributed load $\mathcal{D}_n$, and the stagewise failure probability $p_n$. They noted that the recursion was not tractable and identified the critical disturbance $d_{\mathrm{critical}}$ by simulation. We show that the recursion telescopes exactly into a one-dimensional monotone map $a_{n+1} = g(a_n)$. This yields the threshold in closed form: $1 - a_0 = d_{\mathrm{critical}}\,(1 + \ln(1 + 1/d_{\mathrm{critical}}))$, or explicitly in terms of the lower branch $W_{-1}$ of the Lambert W function. We prove a sharp dichotomy. For $d_m \le d_{\mathrm{critical}}$ the cascade halts with limiting load $a_0 + d_{\mathrm{critical}}$ at criticality and surviving fraction $1/(1 + d_{\mathrm{critical}})$. For $d_m > d_{\mathrm{critical}}$ a complete outage occurs in finitely many steps.
提交历史
来自:Sachin Kadloor[v1] 2026年11月23日 星期一 16:15:00 UTC (20 KB)