跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

电气工程与系统科学 > 图像与视频处理

arXiv:2611.33234 (eess)
[提交于 2026年11月24日]

标题:Diagnostically Meaningful, Privacy-aware Synthetic Chest CT via Class-Conditional Latent Sampling in Diffusion Autoencoders

作者:Johannes B. Thalhammer, Kacper Ogórek, Tina Dorosti, Sebastian Peterhansl, Daniel Frey, Zijin Huang, Theresa Hiu, Tobias Lasser, Daniela Pfeiffer, Franz Pfeiffer, Florian Schaff
查看论文《Diagnostically Meaningful, Privacy-aware Synthetic Chest CT via Class-Conditional Latent Sampling in Diffusion Autoencoders》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Large, well-annotated datasets are essential for developing medical artificial intelligence models, yet data sharing is often restricted by privacy regulations. Synthetic images may help address this limitation if they preserve diagnostic information while reducing the risk of reproducing patient data. We developed a diffusion autoencoder-based framework for class-conditional synthetic chest CT generation that incorporates latent-space distance filtering to reduce the likelihood of regenerating training samples. A diffusion autoencoder was trained on the public RSNA 2020 Pulmonary Embolism (PE) dataset. PE-positive and PE-negative images were synthesized by sampling latent representations from class-specific kernel density estimates. Samples with a nearest-neighbor latent-space distance below a predefined threshold were rejected. To assess diagnostic utility, ResNet-50 classifiers were trained across 10 independent runs using real, synthetic, or mixed real-synthetic datasets. Performance was evaluated on a held-out real test set using the area under the receiver operating characteristic curve (AUC), with DeLong 95% confidence intervals (CIs). Models trained on synthetic data achieved an AUC of 0.862 (95% CI, 0.851-0.874), only slightly lower than models trained on real data (AUC = 0.872, 95% CI, 0.861-0.883) and mixed real-synthetic data (AUC = 0.865, 95% CI, 0.855-0.876). These differences were statistically significant (p < 0.05) but small in absolute terms. A nearest-neighbor copy-detection analysis of 38,000 synthetic slices found no direct copies of real training images. These findings indicate that the synthetic CT images preserve diagnostically meaningful information for image-level PE classification while incorporating measures intended to enhance privacy awareness and reduce similarity to real patient data.
主题: 图像与视频处理 (eess.IV); 人工智能 (cs.AI)
引用方式: arXiv:2611.33234 [eess.IV]
  (或者 arXiv:2611.33234v1 [eess.IV] 对于此版本)
  https://doi.org/10.48550/arXiv.2611.33234

提交历史

来自:Johannes Thalhammer
[v1] 2026年11月24日 星期二 11:25:08 UTC (7,456 KB)
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

eess.IV
< 上一篇   |   下一篇 >
最新 | 近期 | 2026-11
切换浏览方式为:
eess
cs.AI

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站