标题:Frame geometry, fascicle extrapolation and leaderboard overfitting in muscle ultrasound
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读摘要:Automated readings of pennation angle, fascicle length and muscle thickness from B-mode ultrasound depend on the geometry of the stored frame and on how fascicles that leave the image are extended, and challenge entries add settings chosen on a small public leaderboard. This study measures all three in one entry of the UMUD Challenge, which scored 309 frames from six screen layouts, 103 on a public and 206 on a private leaderboard. The pipeline applies layout-specific values of scale and pixel aspect, resamples each frame to square pixels, segments aponeuroses and fascicle fragments with U-Nets and measures the three readings geometrically; the submitted entry blended its angle and length with public notebooks. Because the score is additive, 65 single-change contrasts from 13 base entries measured each decision on both splits. The primary selected entry scored 0.27608 on the private split, the 69th reported position of 690 teams. Reading every frame with square pixels cost 0.029 public and 0.037 private. Of 20 late-stage corrections, 9 kept the sign of their effect on the private split. An audit of the UMUD expert benchmark found that 26 of its 35 frames share their tissue with training images of both DL_Track_US and the challenge. On the 9 frames with no detected match in either set or orientation, the recipe scored 0.213, two experts against two others 0.218 and DL_Track_US 0.263 (0.209, 0.196 and 0.259 when both raters of a reference pair are required), with no difference established. Frame geometry and the extension rule moved readings as much as the choice of model, and small corrections tuned on about 100 public frames did not carry over.
提交历史
来自:Soheil Kooklan[v1] 2026年11月24日 星期二 23:30:28 UTC (10,508 KB)