标题:A Real-Time Low-Cost Platform for Non-Contact Respiratory Rate Monitoring: A Comparative Evaluation of RGB Optical Flow and Time-of-Flight Depth Sensing

作者:Dominik Jasiówka, Patryk Ciężarek, Joanna Zysnawska, Ludwin Molina Arias
查看论文《A Real-Time Low-Cost Platform for Non-Contact Respiratory Rate Monitoring: A Comparative Evaluation of RGB Optical Flow and Time-of-Flight Depth Sensing》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Respiratory rate (RR) is one of the earliest indicators of clinical deterioration, which makes its continuous measurement clinically valuable. In routine practice, however, RR is monitored almost exclusively with contact-based sensors, which require skin attachment, may alter natural breathing, and are poorly tolerated by vulnerable groups such as newborns and elderly patients. Non-contact sensing removes these constraints, with RGB video and depth imaging among its most accessible modalities. In this work, we present a low-cost, real-time platform based on a single multimodal sensor that provides both RGB and time-of-flight (ToF) data streams, implemented on a Raspberry Pi 5 edge device. The system integrates three RGB optical-flow pipelines, namely Farneb\"ack, Horn--Schunck, and Lucas--Kanade, together with a depth-based pipeline incorporating region-of-interest stabilization and distance-derived signal extraction, enabling the two modalities to be evaluated independently under the same experimental protocol. The proposed approach was evaluated on twelve healthy volunteers following a controlled protocol, including normal breathing, hyperventilation, and breath-holding, using a piezoresistive respiratory belt as a reference. RGB-based methods achieved lower RR estimation errors, with Lucas--Kanade attaining the lowest median MAE (3.83 BPM), whereas the ToF-based pipeline, although less accurate for RR estimation (median MAE 6.24 BPM), reached a higher apnea detection sensitivity (0.66 vs 0.51-0.55). These findings highlight the complementary strengths of both modalities and support their integration into unified low-cost platforms.
主题: 信号处理 (eess.SP)
引用方式: arXiv:2611.34599 [eess.SP]
  (或者 arXiv:2611.34599v1 [eess.SP] 对于此版本)
  https://doi.org/10.48550/arXiv.2611.34599

提交历史

来自:Ludwin Molina Arias
[v1] 2026年11月25日 星期三 15:57:28 UTC (872 KB)
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

eess.SP
< 上一篇   |   下一篇 >
最新 | 近期 | 2026-11
切换浏览方式为:
eess

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站