跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

物理学 > 医学物理

arXiv:2611.34605 (physics)
[提交于 2026年11月25日]

标题:Fewer Fractions, Equieffective Plans: An optimization framework based on equieffective dose

作者:Suryakant Kaushik, Jakob Ödén, Albin Fredriksson, Iuliana Toma-Dasu
查看论文《Fewer Fractions, Equieffective Plans: An optimization framework based on equieffective dose》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Background: Non-standard fractionation requires caution before clinical use, and planners often need to manually modify the prescription and dose constraints for non-linear biological effects. Purpose: To develop an extension within a treatment planning system that enables the generation of hypofractionated plans based on equieffective dose, $EQD_{n_{ref}}$, for an alternative fractionation deliverable in $n$ fractions, such that it is equieffective with the reference fractionation for a specified biological endpoint. Methods: A research build of RayStation v2025 was extended to optimize $EQD_{n_{ref}}$ plans. This study used anonymized data from three head and neck patients. $\text{CTV}_p$ and $\text{CTV}_n$ were prescribed 70 Gy and 54 Gy in 35 fractions. Targets, spinal cord, and brainstem were robustly optimized for $\pm3.5$% density and $\pm3.0$ mm setup uncertainties. For each patient, hypofractionated plans were created with 34, 32, 30, and 25 fractions. Sensitivity analysis evaluated the impact of $\alpha/\beta$ uncertainty. Results: All equieffective hypofractionated plans maintained target coverage and met mandatory clinical goals for organs-at-risk (OARs). Compared to standard fractionation, DVH parameters indicated an average $\Delta EQD_{n_{ref}}$ <0.2 Gy for $\text{CTV}_p$ and no difference for $\text{CTV}_n$. For parallel OARs, the median mean-dose difference between hypofractionation (to 30 fractions) and standard fractionation was generally <1% of the prescribed dose. $\alpha/\beta$ uncertainty produced the greatest variation in the 25-fraction regimen, with absolute $\Delta EQD_{n_{ref}}$ up to 0.88 Gy for targets and up to 0.63 Gy for the spinal cord and brainstem. Conclusions: An $EQD_{n_{ref}}$-based framework can generate equieffective hypofractionated plans, making it feasible to reduce fractions without substantially deviating from existing clinical protocols.
主题: 医学物理 (physics.med-ph)
引用方式: arXiv:2611.34605 [physics.med-ph]
  (或者 arXiv:2611.34605v1 [physics.med-ph] 对于此版本)
  https://doi.org/10.48550/arXiv.2611.34605

提交历史

来自:Suryakant Kaushik
[v1] 2026年11月25日 星期三 15:58:10 UTC (1,481 KB)
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.med-ph
< 上一篇   |   下一篇 >
最新 | 近期 | 2026-11
切换浏览方式为:
physics

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站