跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

物理学 > 仪器与探测器

arXiv:physics/0208090 (physics)
[提交于 2002年8月26日]

标题:Proton Irradiation Experiment for the X-ray Charge-Coupled Devices of the Monitor of All-sky X-ray Image mission onboard the International Space Station: I. Experimental Setup and Measurement of the Charge Transfer Inefficiency

作者:E. Miyata, T. Kamazuka, H. Kouno, M. Fukuda M. Mihara, K. Matsuta, H. Tsunemi, K. Tanaka, T Minamisono, H. Tomida, K. Miyaguchi
查看论文《Proton Irradiation Experiment for the X-ray Charge-Coupled Devices of the Monitor of All-sky X-ray Image mission onboard the International Space Station: I. Experimental Setup and Measurement of the Charge Transfer Inefficiency》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:We have investigated the radiation damage effects on a CCD to be employed in the Japanese X-ray astronomy mission including the Monitor of All-sky X-ray Image (MAXI) onboard the International Space Station (ISS). Since low energy protons release their energy mainly at the charge transfer channel, resulting a decrease of the charge transfer efficiency, we thus focused on the low energy protons in our experiments. A 171 keV to 3.91 MeV proton beam was irradiated to a given device. We measured the degradation of the charge transfer inefficiency (CTI) as a function of incremental fluence. A 292 keV proton beam degraded the CTI most seriously. Taking into account the proton energy dependence of the CTI, we confirmed that the transfer channel has the lowest radiation tolerance. We have also developed the different device architectures to reduce the radiation damage in orbit. Among them, the ``notch'' CCD, in which the buried channel implant concentration is increased, resulting in a deeper potential well than outside, has three times higher radiation tolerance than that of the normal CCD. We then estimated the charge transfer inefficiency of the CCD in the orbit of ISS, considering the proton energy spectrum. The CTI value is estimated to be 1.1e-5 per each transfer after two years of mission life in the worse case analysis if the highest radiation-tolerant device is employed. This value is well within the acceptable limit and we have confirmed the high radiation-tolerance of CCDs for the MAXI mission.
评论: 17 pages, 2 table, 12 figures. Accepted for publication of Japanese Journal of Applied Physics. High resolution file is available from http://wwwxray.ess.sci.osaka-u.ac.jp/~miyata/paper/proton_cti.pdf
主题: 仪器与探测器 (physics.ins-det); 天体物理学 (astro-ph); 空间物理 (physics.space-ph)
引用方式: arXiv:physics/0208090 [physics.ins-det]
  (或者 arXiv:physics/0208090v1 [physics.ins-det] 对于此版本)
  https://doi.org/10.48550/arXiv.physics/0208090
相关 DOI: https://doi.org/10.1143/JJAP.41.7542

提交历史

来自:Emi Miyata
[v1] 2002年8月26日 星期一 20:52:36 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.ins-det
< 上一篇   |   下一篇 >
最新 | 近期 | 2002-08
切换浏览方式为:
physics
astro-ph
physics.space-ph

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站