标题:Effect of noise and modeling errors on the reliability of fully 3D Monte Carlo reconstruction in SPECT

作者:D. Lazaro, Z. El Bitar, V. Breton, I. Buvat
查看论文《Effect of noise and modeling errors on the reliability of fully 3D Monte Carlo reconstruction in SPECT》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:We recently demonstrated the value of reconstructing SPECT data with fully 3D Monte Carlo reconstruction (F3DMC), in terms of spatial resolution and quantification. This was shown on a small cubic phantom (64 projections 10 x 10) in some idealistic configurations. The goals of the present study were to assess the effect of noise and modeling errors on the reliability of F3DMC, to propose and evaluate strategies for reducing the noise in the projector, and to demonstrate the feasibility of F3DMC for a dataset with realistic dimensions. A small cubic phantom and a realistic Jaszczak phantom dataset were considered. Projections and projectors for both phantoms were calculated using the Monte Carlo simulation code GATE. Projectors with different statistics were considered and two methods for reducing noise in the projector were investigated: one based on principal component analysis (PCA) and the other consisting in setting small probability values to zero. Energy and spatial shifts in projection sampling with respect to projector sampling were also introduced to test F3DMC in realistic conditions. Experiments with the cubic phantom showed the importance of using simulations with high statistics for calculating the projector, and the value of filtering the projector using a PCA approach. F3DMC was shown to be robust with respect to energy shift and small spatial sampling off-set between the projector and the projections. Images of the Jaszczak phantom were successfully reconstructed and also showed promising results in terms of spatial resolution recovery and quantitative accuracy in small structures. It is concluded that the promising results of F3DMC hold on realistic data sets
主题: 医学物理 (physics.med-ph)
引用方式: arXiv:physics/0412112 [physics.med-ph]
  (或者 arXiv:physics/0412112v1 [physics.med-ph] 对于此版本)
  https://doi.org/10.48550/arXiv.physics/0412112
期刊参考: Dans Proceedings (2004) 1-4 - Conference: IEEE Nuclear Science Symposium And Medical Imaging Conference (NSS / MIC) (2004-10-16 to 2004-10-22), Rome (it)
相关 DOI: https://doi.org/10.1109/NSSMIC.2004.1462770

提交历史

来自:Jeanine Pellet
[v1] 2004年12月17日 星期五 14:49:10 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.med-ph
< 上一篇   |   下一篇 >
最新 | 近期 | 2004-12
切换浏览方式为:
physics

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站