跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

物理学 > 医学物理

arXiv:2302.02967 (physics)
[提交于 2024年8月9日]

标题:TOF MLEM Adaptation for the Total-Body J-PET with a Realistic Analytical System Response Matrix

作者:R. Y. Shopa, J. Baran, K. Klimaszewski, W. Krzemień, L. Raczyński, W. Wiślicki, K. Brzeziński, N. Chug, A. Coussat, C. Curceanu, E. Czerwiński, M. Dadgar, K. Dulski, J. Gajewski, A. Gajos, B. C. Hiesmayr, E. Kavya Valsan, G. Korcyl, T. Kozik, D. Kumar, Ł. Kapłon, G. Moskal, S. Niedźwiecki, D. Panek, S. Parzych, E. Pérez del Rio, A. Ruciński, S. Sharma, Shivani, M. Silarski, M. Skurzok, E. Stȩpień, F. Tayefi Ardebili, K. Tayefi Ardebili, P. Moskal
查看论文《TOF MLEM Adaptation for the Total-Body J-PET with a Realistic Analytical System Response Matrix》的 PDF
查看中文 PDF 查看原文 PDF EasyResearch 阅读
摘要:We report a study of the original image reconstruction algorithm based on the time-of-flight maximum likelihood expectation maximisation (TOF MLEM), developed for the total-body (TB) Jagiellonian PET (J-PET) scanners. The method is applicable to generic cylindrical or modular multi-layer layouts and is extendable to multi-photon imaging. The system response matrix (SRM) is represented as a set of analytical functions, uniquely defined for each pair of plastic scintillator strips used for the detection. A realistic resolution model (RM) in detector space is derived from fitting the Monte Carlo simulated emissions and detections of annihilation photons on oblique transverse planes. Additional kernels embedded in SRM account for TOF, parallax effect and axial smearing. The algorithm was tested on datasets, simulated in GATE for the NEMA IEC and static XCAT phantoms inside a 24-module 2-layer TB J-PET. Compared to the reference TOF MLEM with none or a shift-invariant RM, an improvement was observed, as evaluated by the analysis of image quality, difference images and ground truth metrics. We also reconstructed the data with additive contributions, pre-filtered geometrically and with non-TOF scatter correction applied. Despite some deterioration, the obtained results still capitalise on the realistic RM with better edge preservation and superior ground truth metrics. The envisioned prospects of the TOF MLEM with analytical SRM include its application in multi-photon imaging and further upgrade to account for the non-collinearity, positron range and other factors.
主题: 医学物理 (physics.med-ph); 计算物理 (physics.comp-ph); 仪器与探测器 (physics.ins-det)
引用方式: arXiv:2302.02967 [physics.med-ph]
  (或者 arXiv:2302.02967v1 [physics.med-ph] 对于此版本)
  https://doi.org/10.48550/arXiv.2302.02967
期刊参考: IEEE Transactions on Radiation and Plasma Medical Sciences 7(5) (2023) 509-520
相关 DOI: https://doi.org/10.1109/TRPMS.2023.3243735

提交历史

来自:Roman Shopa Y
[v1] 2024年8月9日 星期五 00:00:00 UTC
全文链接:

访问论文:

  • 查看中文 PDF
  • 查看原文 PDF
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.med-ph
< 上一篇   |   下一篇 >
最新 | 近期 | 2024-08
切换浏览方式为:
physics
physics.comp-ph
physics.ins-det

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站